The anesthetic machine is very essential piece of tool to most veterinary practices. You can find many different brands of machines and few standards related to the design and manufacture. You should get anesthesia machine repair technician and maintenance, as well as regular service of the anesthetic machine, which is an important part of the standard operating procedure of any practice to maximize patient safety.
Anesthesia machine repair and maintenance:
Repair and maintenance includes daily, weekly, and/or monthly procedures performed to keep the machine in optimum working condition. This also involves changing the soda sorbs, filling the vaporizer, removing moisture, and cleaning the machine. They are like routine and simple tasks but if not performed properly may compromise the proper function of the machine. Regular services and preventative maintenance is commonly performed annually and includes the partition of the machine and inspection of all components. Each component is replaced as necessary and the high pressure, low pressure, and respiration system are verified. This would also involve standardization verification of the vaporizer. This should be done by an honorable service company that carries one million dollars of liability insurance. These 2, the regular care and routine preventive maintenance will assure reliable operation of the anesthetic machine.
Components that require delicate repair of anesthesia machine :
1. Flow meter needle valve-
The flow meter needle valve must be operated with carefulness. While turning the valve down, stop when the indicator in the flow tube reaches the bottom. Trying to spin the knob may result in temporary or permanent damage to the needle valve. It would be positive for flow meters that have a positive stop on the knob. In case the flow gauge does not drop to the bottom, this signifies a problem with the needle valve and may require a new needle valve. It is not complex to change the needle valve on most flow meters. An unused needle valve can be buying from most anesthesia companies and will comprise directions for installation. Sometimes, the flow indicator in the flow meter will not drop to the bottom of the flow tube as the indicator and/or the flow tube are unwashed. It needs the elimination of the flow tube and indicator to be cleaned.
2. Vaporizer-
The vaporizer is the most costly and accurate component of the anesthetic machine. In case the vaporizer needs service or recalibration, it is important to execute those procedures off site. Moreover, there are some routine procedures that can prevent issues with the vaporizer. If the vaporizer is a funnel fill style, the O-ring on the cap as well as the funnel, should be dried with a moist gauze sponge each time the vaporizer is filled. If the vaporizer is a component fill, the adapter for the agent bottle should be stored in a clean place. The plug on a key fill vaporizer that is removed to fill the vaporizer should be wiped in equal intervals. The elimination of any foreign material enables that the vaporizer will seal properly when it is closed. It also protects foreign material from getting inside the vaporizer.
To know more about Anesthesia machine repair, visit - Omimedtech.